Parametric Study
This study investigated the effect of outer vacuum shell temperature
on dewar performance. Three different computer runs were made. Heat load
on the cryogen is a key parameter to watch when studying dewar performance.
The values shown below were extracted from the output file.
OS TEMP Heat Load
(K) (mW)
------------------------
150.0 155.44
200.0 203.81
250.0 297.83
Also of interest are the different component temperatures. These were tabulated
using the COMPARE utility in the TAK 2000 WorkBench
Steady State Temperature Comparison
Run Date: 03/05/95
Run Time: 14:55:32
Temp. File 1 Units: Kelvin Filename: dewar1.fin
Temp. File 2 Units: Kelvin Filename: dewar2.fin
Temp. File 3 Units: Kelvin Filename: dewar3.fin
Output Units: Same as Input Units.
Node File 1 File 2 File 3 Node Description
1 134.31 178.95 223.42 Clevis
117 5.10 4.52 3.81 Hot MIC
118 3.70 3.70 3.70 Cold MIC
220 9.92 10.35 9.53 Forward Baffle
260 2.30 2.19 2.06 Secondary Mirror
261 2.30 2.19 2.06 Chopper Motor and Housing
280 69.21 114.38 158.35 FGS
301 18.89 29.14 39.64 IVCS
401 32.44 56.64 83.70 MVCS
501 64.65 110.33 154.90 OVCS
621 63.53 104.69 144.02 Strap, outer
622 34.28 59.63 86.69 Strap, mid
623 21.80 36.46 53.16 Strap, inner
800 1.70 1.70 1.70 MCT (main cryo tank)
900 150.00 200.00 250.00 Outer Shell